48 research outputs found

    Objective methods of monitoring usage of orthotic devices for the extremities: a systematic review

    Get PDF
    Orthoses are commonly prescribed to relieve symptoms for musculoskeletal and neurological conditions; however, patients stop wearing orthoses as recommended for many reasons. When considering the effectiveness of orthoses, there needs to be an objective way to monitor whether participants wear the orthosis as instructed, because if this is not followed, the orthoses will not work as intended. This review aimed to identify, summarise, and compare objective methods used to measure compliance with orthoses applied to the extremities. Databases (Scopus, Web of Science, Embase, CINAHL, and MEDLINE) were searched for eligible studies. Twenty-three studies were accepted in the final review, including five studies that employed upper limb orthoses, two that employed hip orthoses, and fifteen that employed lower limb orthoses. To measure compliance objectively, studies utilised temperature sensors, pressure sensors, accelerometers, a step counter, or a combination of sensors. All sensor types have their own advantages and disadvantages and should be chosen based on study-specific parameters. Sensor-derived monitoring provides quantitative, objective data that are beneficial in both clinical and research settings. The ideal solution to monitoring compliance would consist of both objective and user-reported aspects that, in combination, would provide an all-encompassing picture of the orthotic treatment prescribed

    Statistical shape modelling of the first carpometacarpal joint reveals high variation in morphology

    Get PDF
    The first carpometacarpal (CMC) joint, located at the base of the thumb and formed by the junction between the first metacarpal and trapezium, is a common site for osteoarthritis of the hand. The shape of both the first metacarpal and trapezium contributes to the intrinsic bony stability of the jointandvariability in the morphology of both these bones can affect the joint’s function. The objectivesof this study wereto quantify the morphological variation of the complete metacarpal and trapeziumand determine anycorrelation between anatomical features ofthese two components of the first CMC joint. A multi-object statistical shape modelling pipeline, consisting of scaling, hierarchical rigid registration, non-rigid registration and projection pursuit principal component analysis, was implemented. Four anatomical measureswere quantified from the shape model, namely the first metacarpal articular tilt and torsion angles and the trapeziumlength and width.Variationsin the first metacarpal articulartilt angle (-6.3°<Ξ<12.3°) and trapezium width (10.28mm <<11.13mm)wereidentified in the firstprincipal component. In the second principal component, variationsin the first metacarpal14torsion angle (0.2°<α<14.2°), first metacarpal articular tilt angle (1.0°<Ξ<6.4°) and trapezium length (12.25mm <ℓ<17.33mm)weredetermined. Due to their implications for joint stability, the first metacarpal articular tilt angle and trapezium width maybe important anatomical features which couldbe used toadvance early detectionand treatment offirst CMC joint osteoarthritis

    Wrist tendon moment arms: Quantification by imaging and experimental techniques

    Get PDF
    Subject-specific musculoskeletal models require accurate values of muscle moment arms. The aim of this study was to compare moment arms of wrist tendons obtained from non-invasive magnetic resonance imaging (MRI) to those obtained from an in vitro experimental approach. MRI was performed on ten upper limb cadaveric specimens to obtain the centrelines for the flexor carpi radialis (FCR), flexor carpi ulnaris (FCU), extensor carpi radialis longus (ECRL), extensor carpi radialis brevis (ECRB), extensor carpi ulnaris (ECU), and abductor pollicis longus (APL) tendons. From these, the anatomical moment arms about each of the flexion-extension (FE) and radioulnar deviation (RUD) axes of the wrist were calculated. Specimens were mounted on a physiologic wrist simulator to obtain functional measurements of the moment arms using the tendon excursion method. No differences were observed between anatomical and functional values of the FE and RUD moment arms of FCR, ECRL and ECRB, and the RUD moment arm of ECU (p>0.075). Scaling the anatomical moment arms relative to ECRB in FE and ECU in RUD reduced differences in the FE moment arm of FCU and the RUD moment arm of APL to less than 15% (p>0.139). However, differences persisted in moment arms of FCU in RUD, and ECU and APL in FE (p<0.008). This study shows that while measurements of moment arms of wrist tendons using imaging do not always conform to values obtained using in vitro experimental approaches, a stricter protocol could result in the acquisition of subject-specific moment arms to personalise musculoskeletal models

    Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment

    No full text
    Fluoroscopic images suffer from multiple modes of image distortion. Therefore, the purpose of this study was to compare the effects of correction using a range of two‐dimensional polynomials and a global approach. The primary measure of interest was the average error in the distances between four beads of an accuracy phantom, as measured using RSA. Secondary measures of interest were the root mean squared errors of the fit of the chosen polynomial to the grid of beads used for correction, and the errors in the corrected distances between the points of the grid in a second position. Based upon the two‐dimensional measures, a polynomial of order three in the axis of correction and two in the perpendicular axis was preferred. However, based upon the RSA reconstruction, a polynomial of order three in the axis of correction and one in the perpendicular axis was preferred. The use of a calibration frame for these three‐dimensional applications most likely tempers the effects of distortion. This study suggests that distortion correction should be validated for each of its applications with an independent “gold standard” phantom

    The effect of planar constraint on the definition of the wrist axes of rotation

    Get PDF
    Instantaneous helical axes (IHAs) and screw displacement axes (SDAs) are commonly used to investigate joint functional axes of rotation. In the wrist, these have often been obtained through in vitro motion analysis. These definitions are then employed for in vivo applications, such as the design of implants or the development of musculoskeletal models. However, functional unguided joint motions are, by definition, affected by the activity of muscles. Previously published data has disagreed on the relative position and orientation of the two primary axes of rotation of the wrist, i.e. the radioulnar deviation (RUD) axes with respect to the flexion-extension (FE) axis. An in vivo study comparing the FE and RUD IHAs and SDAs of guided motions, to replicate in vitro conditions, and unguided motions of 23 healthy participants was conducted using optical motion capture. Guided motions were performed with the hand and forearm flush against a flat surface. The relative position and orientation of the RUD SDAs with respect to the FE SDAs differed (p = 0.019, p = 0.001) between unguided FE and guided RUD (0.1 ± 4.3 mm, 93.5 ±16.0°) and guided FE and RUD (1.6 ± 4.0 mm, 107.8 ±17.7°). This indicates that the use of different constraints, and not physiological differences, is the cause for differences in the relative positions and orientations of the FE and RUD axes in the literature. Thus, the practice of using in vitro definitions of the axes of rotation of the wrist for in vivo applications, especially involving FE, may be inappropriate and care must be taken to account for any constraint on wrist motion. It is recommended that investigators define the axes of rotation specifically for their study or refer to literature featuring the desired levels of constraint

    Validation of two-dimensional video-based inference of finger kinematics with pose estimation

    Get PDF
    Accurate capture finger of movements for biomechanical assessments has typically been achieved within laboratory environments through the use of physical markers attached to a participant’s hands. However, such requirements can narrow the broader adoption of movement tracking for kinematic assessment outside these laboratory settings, such as in the home. Thus, there is the need for markerless hand motion capture techniques that are easy to use and accurate enough to evaluate the complex movements of the human hand. Several recent studies have validated lower-limb kinematics obtained with a marker-free technique, OpenPose. This investigation examines the accuracy of OpenPose, when applied to images from single RGB cameras, against a ‘gold standard’ marker-based optical motion capture system that is commonly used for hand kinematics estimation. Participants completed four single-handed activities with right and left hands, including hand abduction and adduction, radial walking, metacarpophalangeal (MCP) joint flexion, and thumb opposition. The accuracy of finger kinematics was assessed using the root mean square error. Mean total active flexion was compared using the Bland–Altman approach, and the coefficient of determination of linear regression. Results showed good agreement for abduction and adduction and thumb opposition activities. Lower agreement between the two methods was observed for radial walking (mean difference between the methods of 5.03°) and MCP flexion (mean difference of 6.82°) activities, due to occlusion. This investigation demonstrated that OpenPose, applied to videos captured with monocular cameras, can be used for markerless motion capture for finger tracking with an error below 11° and on the order of that which is accepted clinically

    Maximum dorsiflexion increases Achilles tendon force during exercise for midportion Achilles tendinopathy

    Get PDF
    Rehabilitation is an important treatment for non-insertional Achilles tendinopathy. To date, eccentric loading exercises (ECC) have been the predominant choice; however, mechanical evidence underlying their use remains unclear. Other protocols, such as heavy slow resistance loading (HSR), have shown comparable outcomes, but with less training time. This study aims to identify the effect of external loading and other variables that influence Achilles tendon (AT) force in ECC and HSR. Ground reaction force and kinematic data during ECC and HSR were collected from 18 healthy participants for four loading conditions. The moment arms of the AT were estimated from MRIs of each participant. AT force then was calculated using the ankle torque obtained from inverse dynamics. In the eccentric phase, the AT force was not larger than in the concentric phase in both ECC and HSR. Under the same external load, the force through the AT was larger in ECC with the knee bent than in HSR with the knee straight due to increased dorsiflexion angle of the ankle. Multivariate regression analysis showed that external load and maximum dorsiflexion angle were significant predictors of peak AT force in both standing and seated positions. Therefore, to increase the effectiveness of loading the AT, exercises should apply adequate external load and reach maximum dorsiflexion during the movement. Peak dorsiflexion angle affected the AT force in a standing position at twice the rate of a seated position, suggesting standing could prove more effective for the same external loading and peak dorsiflexion angle

    Simulated activities of daily living do not replicate functional upper limb movement or reduce movement variability

    Get PDF
    © 2018 The Authors. Kinematic assessments of the upper limb during activities of daily living (ADLs) are used as an objective measure of upper limb function. The implementation of ADLs varies between studies; whilst some make use of props and define a functional target, others use simplified tasks to simulate the movements in ADLs. Simulated tasks have been used as an attempt to reduce the large movement variability associated with the upper limb. However, it is not known whether simulated tasks replicate the movements required to complete ADLs or reduce movement variability. The aim of this study is to evaluate the use of simulated tasks in upper limb assessments in comparison to functional movements. Therefore answering the following questions: Do simulated tasks replicate the movements required of the upper limb to perform functional activities? Do simulated tasks reduce intra- and inter-subject movement variability? Fourteen participants were asked to perform five functional tasks (eat, wash, retrieve from shelf, comb and perineal care) using two approaches: a functional and a simulated approach. Joint rotations were measured using an optoelectronic system. Differences in movement and movement variability between functional and simulated tasks were evaluated for the thorax, shoulder, elbow/forearm and wrist rotations. Simulated tasks did not accurately replicate the movements required for ADLs and there were minimal differences in movement variability between the two approaches. The study recommends the use of functional tasks with props for future assessments of the upper limb

    Design and Evaluation of Magnetic Hall Effect Tactile Sensors for Use in Sensorized Splints

    Get PDF
    Splinting techniques are widely used in medicine to inhibit the movement of arthritic joints. Studies into the effectiveness of splinting as a method of pain reduction have generally yielded positive results, however, no significant difference has been found in clinical outcomes between splinting types. Tactile sensing has shown great promise for the integration into splinting devices and may offer further information into applied forces to find the most effective methods of splinting. Hall effect-based tactile sensors are of particular interest in this application owing to their low-cost, small size, and high robustness. One complexity of the sensors is the relationship between the elastomer geometry and the measurement range. This paper investigates the design parameters of Hall effect tactile sensors for use in hand splinting. Finite element simulations are used to locate the areas in which sensitivity is high in order to optimise the deflection range of the sensor. Further simulations then investigate the mechanical response and force ranges of the elastomer layer under loading which are validated with experimental data. A 4 mm radius, 3 mm-thick sensor is identified as meeting defined sensing requirements for range and sensitivity. A prototype sensor is produced which exhibits a pressure range of 45 kPa normal and 6 kPa shear. A proof of principle prototype demonstrates how this can be integrated to form an instrumented splint with multi-axis sensing capability and has the potential to inform clinical practice for improved splinting